বাড়ি পণ্যAC Contactor

30mA 100mA 300mA Earth Leakage Switch Residual Current 2 Phase Circuit Breaker

সাক্ষ্যদান
চীন Shenzhen City Breaker Co., Ltd. সার্টিফিকেশন
চীন Shenzhen City Breaker Co., Ltd. সার্টিফিকেশন
Excellent quality and fast delivery.

—— Victor

I want to say that your products very good. Thank you for all your suggestion, also good after sales service.

—— Mr Abílio Cipriano

Easy to talk with, very professional and fast service, the flag quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

তোমার দর্শন লগ করা অনলাইন চ্যাট এখন

30mA 100mA 300mA Earth Leakage Switch Residual Current 2 Phase Circuit Breaker

30mA 100mA 300mA Earth Leakage Switch Residual Current 2 Phase Circuit Breaker
30mA 100mA 300mA Earth Leakage Switch Residual Current 2 Phase Circuit Breaker

বড় ইমেজ :  30mA 100mA 300mA Earth Leakage Switch Residual Current 2 Phase Circuit Breaker

পণ্যের বিবরণ:
Place of Origin: Zhejiang,China(Mainland)
পরিচিতিমুলক নাম: JIELI
সাক্ষ্যদান: CE/ISO9001/IEC60898-1
Model Number: JL-NFIN
প্রদান:
Minimum Order Quantity: 1200 Piece/Pieces other
মূল্য: Negotiable
Packaging Details: Standard export carton or according to your request.
Delivery Time: Within 20 days
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,CASH
Supply Ability: 50000POLES/DAY
বিস্তারিত পণ্যের বর্ণনা
লক্ষণীয় করা:

earth leakage circuit breaker

,

elcb circuit breaker

 

30mA/100mA/300mA earth leakage switch residual current circuit breaker

 

 

Quick Detail:

 

 

 

Place of Origin:

Zhejiang China (Mainland)

Brand Name:

JIELI OEM/ODM

Model Number:

JL-NFIN residual current circuit breaker

Type:

Earth Leakage, Electronic or magnetic residual current circuit breaker

Poles Number:

2P/4P

Rated current(A):

16-100

Rated voltage(V):

230/400

Rated residual non-operating current(mA):

0.5 ≤I n

Rated residual operating current(mA):

30mA,300mA

Color:

White

Point:

silver

Residual current off-time:

≤0.3s

Parts:

brass/copper

 

 

 

 

 

Description:

 

 

 

JL-NFIN Residual current circuit breaker ID is used for protection against indirect touching of parts under voltage, for prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of In<30mA.

JL-NFIN residual current circuit breaker/rccb/rcd/elcb can be used in TN-S, TT and IT network systems or with other words in all systems where neutral and protective conductor are separated(VDE 0100 Teil 410).

 

Specifications:

 

 

 

Product name

JL-NFIN 

Standard

IEC61008/GB16196

Product Certifications

CE,CB,3C

Product Function

Leakage protection, Isolation function

Rated current(A)

<25   <40  <63

Pole No

1P+N  3P+N

Rated voltage(V)

230V/400V

Rated frequency(Hz)

50/60

Sensitivity (In)

30mA,100mA,300mA

Environment  temperature

-25°C-+60°C

Connection type

Tunnel style, Pin style, U style

Biggest wiring ability

35mm2

Action  style

AC22

Installation style

35mm standard 35mm guide

Im,Im(A)

500

Inc,Ic(A)

6000

Mechanical life

10000

Protection degree

IP20

 

About our company-JIELI:

 

 

 

1.JIELI Electrical is abbreviation for" Alliance of JIELI Electrical Industry", with JILI brand and ICEDC brand.

2.JIELI Electrical have 29 members and more than 2000 employers, all of the plants area are about 50000 square meters.

3.JIELI Electrical devoted in producing low-voltage circuit breaker and other related products. .

4.At present, JIELI main products MCB,MCCB,RCCB, Distribution box, AC contactor, Relay, Switch and more than thousands electrical goods spare parts.

 

Our service:

 

 

 

1. Samples: provide free samples.

2. Package: all products will be well packed before shipping.

3. Warranty: all products have 2-5 years warranty.

4. Delivery: within 30days after received the deposit.

5. Provide OEM and ODM service.

6. We can help you with any of your idea to design and put it into production.

7.Provide help for building factories, such as: spare parts, technical questions, financial matter, management problem , approach of sales...

 

Store:

 

 

 

when the products need store for a long time, not control the products store environment, the metal and the paint coat will be corroded. So, pay attention to:

1)Products must store with room temperature and dry environment. Sealing when under high humidity environment.

2)Don't store the products with acid volatile liquid and acid gas together. Don't store in high dust environment.

3)Don't store the products in high temperature and humidity or lowest temperature for a long time, please install and use as soon as possible.

4)Don't contact the link wire before products used normally, preventing corrosion from pre-contacting.

5)Please inform and operate under the manufacturer' advise referring to special store environment such as high temperature and humidity islands near equator, ultra-low temperature area.

যোগাযোগের ঠিকানা
Shenzhen City Breaker Co., Ltd.

ব্যক্তি যোগাযোগ: Mr. fov

টেল: 18810166789

ফ্যাক্স: 86-189-4289-0330

আমাদের সরাসরি আপনার তদন্ত পাঠান (0 / 3000)