বাড়ি পণ্যFlexible Membrane Switch

Fieldbus Communication Gas Temperature Transmitter Self - diagnostic

সাক্ষ্যদান
চীন Shenzhen City Breaker Co., Ltd. সার্টিফিকেশন
চীন Shenzhen City Breaker Co., Ltd. সার্টিফিকেশন
Excellent quality and fast delivery.

—— Victor

I want to say that your products very good. Thank you for all your suggestion, also good after sales service.

—— Mr Abílio Cipriano

Easy to talk with, very professional and fast service, the flag quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

তোমার দর্শন লগ করা অনলাইন চ্যাট এখন

Fieldbus Communication Gas Temperature Transmitter Self - diagnostic

Fieldbus Communication Gas Temperature Transmitter Self - diagnostic
Fieldbus Communication Gas Temperature Transmitter Self - diagnostic

বড় ইমেজ :  Fieldbus Communication Gas Temperature Transmitter Self - diagnostic

পণ্যের বিবরণ:
Place of Origin: China or Japan
পরিচিতিমুলক নাম: Yokogawa
সাক্ষ্যদান: FM, CENELEC ATEX, CSA, IECEx
Model Number: YTA
প্রদান:
Minimum Order Quantity: 1pc
Packaging Details: In carton or as customer’s requirement
Delivery Time: 6~8weeks
Payment Terms: T/T, L/C, PayPal, Western Union, Cash, Escrow
Supply Ability: 100pcs
বিস্তারিত পণ্যের বর্ণনা
output signal: Two wire 4-20mA DC Mounting: two-inch pipe or flat panel mounting
Weight: 1.2 kg(2.6 lb) Supply Voltage: 10.5 to 42 V DC for general use and flameproof type
Terminals: M3 screws Coating: Polyurethan resin baked finish
Protocol: FF Integral Indicator: with LCD display
লক্ষণীয় করা:

Temperature transmitter

,

Rosemount Temperature transmitter

Fieldbus Communication Gas Temperature Transmitter Self - diagnostic 

 

 

Quick Detail:

 

      Fieldbus is the digital communication line for the field
      instruments, whose signal is internationally standardized by Fieldbus Foundation.
      The Fieldbus bi-directional digital communication
      performance makes possible for the field instruments
      and the control devices to be a complete on-line
      system, superseding the existing analog transmission
      lines. Also, the precise transmission of various
      process data including the PV and MV of the field
      instruments is well established by the Fieldbus multisensing function. Thus, based on FOUNDATION
      Fieldbus specifications, YTA320 Fieldbus model offers
      more flexible instrumentation through a higher level
      communication capability and proposes the cost
      reduction by multi-drop wirings with less cables.

 

 

FEATURES:

 

● Interoperability
FOUNDATION Fieldbus specifications grant the
interoperability of the field instruments without
preparing designated softwares for the instrument.
● Reduction of instrumentation cost
The multi-drop wiring on the Fieldbus communication
line contributes to the reduction of wiring cost.
● Four AI and DI function blocks
YTA320 Fieldbus model has four independent AI
function blocks whose input can be selected from
Sensor1 input, Sensor2 input, terminal temperature,
differential temperature, average temperature, and
back-uped input. Four DI function blocks can be
used as a limit switch for those temperature.
● Alarm function
YTA Fieldbus models securely support various alarm
functions, such as high/low alarm, notice of block
error, etc. based on FOUNDATION Fieldbus specifications.
● Self-diagnostic function
The reliable self-diagnostic function detects such
failure as measuring range failure and abnormal
ambient temperature, as well as the hardware failure.
● PID function block (option)
PID function block enables field devices to control
processes. Up to two blocks can be specified.

 

 

STANDARD SPECIFICATIONS


For items other than those described below, refer
to GS 01C50B02-00E.
Applicable Model:
YTA320
Output Signal:
Digital communication signal based on FOUNDATION Fieldbus protocol.
Supply Voltage:
9 to 32 V DC for general use, flameproof type,
Type n, or nonincendive
9 to 24 V DC for intrinsically safe type Entity model
9 to 17.5 V DC for intrinsically safe type FISCO
model
Conditions of Communication Line:
Supply Voltage: 9 to 32 V DC
Supply Current: 16.6 mA (max)
Functional Specifications:
Functional specifications for Fieldbus communication
conform to the standard specifications (H1) of
FOUNDATION Fieldbus.
Function Block: Four AI function blocks
Four DI function blocks
One/Two PID function blocks (option)
Link Master function

 

 

Application

Electrolyzer Solution: Instruments and Solution for Ion-Membrane Electrolyzer Plant Application

Caustic soda and hydrochloric acid, produced in electrolyzer plants, are fundamental materials used in varieties of industries; chemicals, pharmaceuticals, petrol-chemicals, pulp and papers, etc. Profit is the result of the effective production with minimized running / maintenance cost. Proper control of the process brings you stabilized quality of products with the vast operational profit.

Measurement in Cogeneration and Captive Power Boiler

Steam is still one of the most popular methods of providing an energy source to a process and its associated operations. The more accurate and reliable measurements that are made, the more informed decisions can be taken that affect costs and product quality.

Industries: Oil & Gas Upstream, Refining, Bulk& Petrochemical, Specialty Chemical, Power, Pulp and Paper, Iron and Steel

 

Pulp & Paper: Instruments and Solution for Pulp & Paper Industry

Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. The improved plant performance translates to the higher quality improvement and lower cost, and simultaneously environmental friendly plant operation.

Industry: Pulp and Paper

   

 

Specifications:

 

Accuracy (typical)

YTA110: ±0.1% of span
YTA310/320: ±0.05% of span

Cold junction Compensation accuracy

(For T/C only) 
±0.5 deg C (0.9 deg F)

Power supply effect

±0.005% of calibration span per volt

Ambient temperature effect

±0.1%/10 deg C (YTA110)

Input signal

YTA110/YTA310: single input, YTA320: dual input
Input type is selectable: thermocouples, 2-, 3-, and 4-wire RTDs, ohm and DC milivolt

Output

Two wire 4 to 20 mA DC or FOUNDATION fieldbus signal (YTA320)

Supply voltage

BRAIN and HART: 10.5 to 42 V DC
(10.5 to 30 V DC for Intrinsically safe type)
Fieldbus: 9 to 32 V DC
(9 to 24 V DC for Entity and 9 to 17.5 V DC for FISCO)

Ambient temperature

Option code may affect limits
-40 to 85 deg C (-40 to 185 deg F)
-30 to 80 deg C (-22 to 176 deg F) with integral indicator

Mounting

Optional mounting bracket can be used either for two-inch pipe or flat panel mounting.

Weight

1.2 kg (2.6lb) without integral indicator and mounting bracket. Integral indicator weighs 0.2kg (0.4lb).

Degrees of protection

IP66, IP67 and NEMA 4X

Certificates

CENELEC, CSA, FM, IECEx or TIIS

SIL Certificate

Certified by TÜV NORD in compliance with the IEC61508 SIL 2 capability for single transmitter use.

 

 

Competitive Advantage:

 

Differential pressure transmitters, which serve as the core of field instrumentation, are widely used to measure the flow rate, pressure and density of liquids, gases and steam, as well as the level of liquid in a tank.

 

যোগাযোগের ঠিকানা
Shenzhen City Breaker Co., Ltd.

ব্যক্তি যোগাযোগ: Mr. fov

টেল: 18810166789

ফ্যাক্স: 86-189-4289-0330

আমাদের সরাসরি আপনার তদন্ত পাঠান (0 / 3000)